Electronic Control
Equipment
Integral Control
Integral Control
A115/00
Why choose an actuator with an integrated
control ?
n
FOR ENGINEERINGS :
When conventional actuators equipped with
position limits, torque limiters and eventually a
proportional transmitter are integrated into a
process, complex electrical equipment must be
installed on site as follows:
l
Simplification and standardization of interface mod-
ules.
l
Makes it possible to choose important functions
before installation.
l
reversing starters,
control components,
l
n
FOR INSTALLATION OF ACTUATORS :
positioners,
l
Easy commissioning thanks to local controls.
l
optional control components,
l
Commissioning is possible with only the power
connected.
l
and so on ...
l
Time savings at commissioning.
l
It includes an additional important savings for :
l electronic board,
l start-up,
l dimensional,
l documentation,
l study.
The INTEGRAL+ includes an important cost savings
in controls because all of the control components are
integrated into the actuator.
n
FOR EASY USAGE :
Capable of modifying the control functions even dur-
ing usage.
l
Installation of additional functions on site at lower
costs.
l
Easy to use thanks to local settings and controls.
l
Local controls are lockable in various positions.
l
Actuator
Control station
Power
Power
supply
Motor
Standard actuator
Control
logic
Control
system
Informations
Inf o rma t ion
Actuator
Control station
Local / Remote
Control
logic
Actuator
with built-in
control
Motor
Power
supply
Control
panel
Info r m a t i on
 
Integral + : a specific control for each need
REMOTE CONTROL
Control by means
of contacts:
External power
supply
Electronic board
with built-in power
supply (24V)
Control by pulse
signal :
Only one pulse
required for open,
close or stop
Proportional
control :
By current :
4-20 mA, 0-20 mA,
4-12 mA, 12-20 mA
By voltage:
0-10 V
Command for local
bus control:
Simple
Redundant
3
Control by
maintained signal :
Actuator continues to
function as long as
the signal is main-
tained and stops
when released
Control by pulse
signal :
One pulse for open,
close or stop
Selector :
Local / Remote
Lockable selector in
all 3 positions
Remotely Allow or
Prohibit local controls
LOCAL CONTROL
Descriptions of possible functions :
n CONTROLS:
E1
n PROTECTION:
P1
í
í
Remote control: Pulse command
Fuses:
by means of contacts:
external power supply
or by electronic board
supplying power (24V)
Protection against short circuit.
l
í
P2
Motor temperature sensor:
maintained signal:
one pulse for open,
close or stop
Efficient protection for the motor against overheating.
If the temperature in the winding is too high, the motor
supply is stopped. Restarting is possible only after the
temperature decreases.
l
without maintained signal:
actuator continues to
function as long as the
signal is maintained
and
l
í
P3
Torque limiteur:
stops
when
released
The electronic board memorizes actions of the torque
limiter and prohibits restarting in the same rotational
direction. This system guaranties a complete full stop
even if the torque limiter pressure is released.
Remote control specifications
Isolated by optocouplers
l
Voltage: 10 to 250V DC/AC
í
l
P4
Phase control:
Current: 10 mA at 24V
l
Protects against incorrect 3 phase connection and
includes an automatic phase correction.
Minimum pulse: 100ms
l
Time of rotational direction change : 50ms or 200ms
l
n
SIGNALING :
4
í
E2
Proportional: (with positioner)
í
L1
Fault relay
l by current: 4 - 20 mA, 0 - 20 mA,
4 - 12 mA, 12 - 20 mA,
l by voltage: 0 - 10 V
Remote selector Proportional / pulse command
ESD: Emergency Shut Down for Open. or Close.
A fault signaling relay detects all malfunctions or unavail-
abilities and communicates this information remotely :
Power supply failure or blown fuse
l
Loss of a phase in 3 Ph
l
Thermal motor protection tripped
l
í
E3
Local control at the actuator:
Selector in "LOCAL" position
l
By pulse signal: one pulse for open, close or stop
No signal 4-20mA (exception: 0-10V or 0-20mA)
l
l
By maintained signal: actuator continues to function
as long as the signal is maintained and stops when
released
l
Possible choices between the following faults:
Torque limiter open / close tripped
l
Local / Remote / Off (stopping) selector lockable in all
3 positions
l
Selector in "LOCAL" position not available
l
“No signal” not available
l
í
E4
Local internal control: (positioner)
í
L2
Remote:
l For commissioning or testing
l Automatic calibration according to selected signal
Timing control (optional)
This optional card will allow extension of the valve oper-
ation speed. The actuator operates by successive pulses
adjusted at the card. One part of the stroke can have a
normal operating speed and the other part an extended
speed control. An auxiliary limit switch gives the order to
switch from normal to slow speed. The adjustments are
independent in both open and close direction. The oper-
ating time for the full valve stroke can be set very long.
The device is used to avoid hammer effects when open-
ing and closing a valve.
- 4 options available from 16 possiblities
- 3 additional options can be added as an option:
Open/Close/Supply
Local (option):
- 3 LED's for Open/Close/Supply
í
L3
Position transmitter: (with positioner)
Transmitting the proportional position signal is of the
same scale as the input control signal
Example
:
input 4-12 mA
output 4-12 mA
Exception :
input 0-10 V
output 0-20 mA
Integral+ Layout
ACTUATOR
Limit switch
Open / Close
Torque limiter
Open / Close
Potentiometer
Motor
Thermal
Hea t er
P2
Reversing
starter
LED's on board
Rotat i on
A uto
phase
correction
Open
Close
Thermal
Torque
direction
Fu s e
P4
Programming
1
P3
A = St an dard
P1
B
A
POSITIONER
Optional
1
E4
2
3
4
PROGRAMMABLE LOGIC
CONTROL
1
23
4
567
89
10
5
6
Fu s e
5
7
TR
Inte r nal
supply
8
9
2
10
11
P1
12
13
LOCAL CONTROL
Reed
contact
Opto-
links
Remote
Off
Local
E3
Fu s e
Supply
24V DC
3
INDICATION
P1
Jumper
A
B
R1
14
A
B
Jumper
R2
15
Jumper
A
B
R3
16
17
18
A
B
Jumper
R4
19
21
20
L1
Fault Relay
L3
L2
E1
E2
L1 L2 L3
+-
Input
Output
Analog
Auxillary
DC
Power
supply
Remote
pulse
control
Remote indications of:
• positions
• status
• alarms
• Controls
• Analog Remote
Position signal
 