VI-505/IC-412
Video Interface Kit/Image Controller
INSTALLATION MANUAL
Applied Machines: C360/C280
COLOR MFP: 36 ppm/28 ppm
Product Code: A0ED
I. Accessory parts
Before starting to set up, check that the following are
included.
Only the parts required to install the image controller
appear in the package contents list.
Package contents of the video interface kit
VI-505
No.
Name
Shape
Q’ty
1.
Relay circuit
board
Package contents of the image controller Fiery
IC-412
1
No.
Name
Shape
Q’ty
A0YEIXC004DA
1.
Image
controller
2.
Power cord *
(For connection
between copier
and IC)
1
1
A0YEIXC002DA
3.
Screw A *
(4 × 8 mm)
1
4040IXC046DA
4.
Shoulder
screws for
mounting the
relay circuit
board
A0YEIXC001DA
2.
Power cord A
2
1
A0YEIXC005DB
5.
Shoulder
screws for the
relay circuit
board connec-
tor
A00HIXC019HA
3.
Power cord B
*1
(for the wall
outlet)
2
1
A0YEIXC047DA
A00HIXE034HA
6.
Upper mount-
ing bracket
4.
Copier
LAN cable
(crossover
cable)
1
1
A00HIXC018HA
A0YEIXC074DA
5.
Image
transmission
cable
7.
Lower mount-
ing bracket
2
1
A00HIXC105HB
8.
Screw B
(3 × 20 mm)
A0YEIXC003DA
4
6.
Ferrite Core
1
9J08IXC075DA
9.
Installation
manual
A0YEIXC054DA
7.
Other accesso-
ries *2
-
-
1 set
*1
This power cord cannot be used in Taiwan that
utilizes 110V power.
4980IXC019DA
*2
The accessories are not used when installing
the image controller.
*
This part is not used when installing the video
interface kit on C360/C280.
A0YE-9560-00
E-1
<Softswitch>
• Lights up when the image controller is running or
is ready to be used.
• When turned on, the image controller system
starts up.
• When turned off, the image controller system
safely shuts down.
Note:
• If the image controller malfunctions or cannot
be shut off with the softswitch, be sure to
unplug the power cord from the electrical outlet
or the machine’s power cord connector.
• Remove the seal from the connector of the
power cord.
After unpacking, be sure to get rid of the
packaging materials and keep them out of
the reach of children.
Putting the head in the plastic bag
involves danger of suffocation.
Note:
This manual provides the illustrations of the acces-
sory parts and machine that may be slightly differ-
ent in shape from yours. In that case, instead of
the illustrations, use the appearance of your
machine to follow the installation procedure. This
does not cause any significant change or problem
with the procedure.
<Port descriptions>
Port 1
II. Part names
Port 2
Ethernet 10Base-T/100Base-TX/1000Base-T
network port (Port 1)
A00HIXC033HB
Port 1 (For the LAN)
Connect the network cable to the LAN.
Port 2 (For the COPIER)*
Use a crossover cable to connect to the LAN port of
the copier.
*
This port is not used, depending on the connec-
tion method. Refer to page E-7.
Power
cord con-
nector
Image transmission
connector
Softswitch LED
Copier LAN cable port (Port 2)
A0YEIXC006DA
E-2
III. Installation procedures
1. Turn off the machine and unplug the power cord
from the power outlet.
2. Remove the cover from the right side of the
machine as shown in the illustration (four
screws).
5. Remove the internal bracket (12 screws).
A0YEIXC057DA
6. Remove the interface connector cover for the
copier (one screw).
(Do not use the removed connector cover.)
A09NIXC024DA
3. If the fax kit has been installed, loosen the two
screws, and then remove the circuit board from
the copier.
A0YEIXC058DA
7. Remove the two screws for the main circuit
board.
Note:
The two screws removed here will be used to
install the relay circuit board.
A0YEIXC073DA
4. Remove the cover from the back of the machine
as shown in the illustration (four screws).
A0YEIXC014DA
A0YEIXC056DA
E-3
8. Attach the two supplied shoulder screws for
mounting the relay circuit board to the main cir-
cuit board.
11. Using the two screws, secure the relay circuit
board.
Note:
Be sure to use the two screws removed in step 7.
A0YEIXC015DB
A0YEIXC017DA
9. Flip the switches 1 and 2 up as shown in the illus-
tration.
Note:
If the switches are not flipped up, this option can-
not be detected properly.
12. Using the two supplied shoulder screws for the
relay circuit board connector, secure the connec-
tor of the relay circuit board.
A0YEIXC018DA
A0YEIXC059DA
13. To install the covers and other parts removed in
steps 4 and 5, reverse the removal procedure.
14. If the fax kit was removed in step 3, install it at
the location from where it was removed.
15. Remove the knockout from the cover removed in
step 2 with nippers.
10. Mount the supplied relay circuit board as shown
in the illustration.
Note:
Align the matchmark of the relay circuit board with
that of the main circuit board. Connect the connec-
tor located on the back of the relay circuit board to
the connector on the main circuit board.
Knockout
A0YEIXC061DA
A0YEIXC060DA
E-4
16. Install the cover removed in step 2 (four screws).
17. Remove the mounting brackets from the image
controller (five screws).
19. Connect the furnished power cord to the image
controller power cord connector and secure the
power cord plug with the clamp.
110-127 V regions: power cord B
220-240 V regions: power cord A
Note:
• Be sure to use the furnished power cord.
•
Power cord for Taiwan that utilizes 110V power
is not supplied as an accessory part.
A0YEIXC064DA
20. Insert the two image controller tabs into the
holes on the machine cover.
A0YEIXC062DA
18. Attach the furnished upper and lower mounting
brackets to the image controller (five screws
removed in step 17).
A0YEIXC065DA
21. Screw the image controller to the cover (four fur-
nished screws B).
Note:
Tighten the two lower screws first.
A0YEIXC063DA
A0YEIXC066DA
E-5
Plik z chomika:
ramirez_pl
Inne pliki z tego folderu:
au-101_im_A09M-9557-00E.pdf
(362 KB)
au-102_im_A0X9-9557-00E.pdf
(359 KB)
au-201_im_A09N-9557-00E.pdf
(431 KB)
bizhub_c360_c280_c220_im_A0ED-9602-11E.pdf
(1623 KB)
df-617_im_A0HU-9560-00E.pdf
(581 KB)
Inne foldery tego chomika:
firmware c280
User Guides
Zgłoś jeśli
naruszono regulamin