July 1998
54AC169 • 54ACT169
4-Stage Synchronous Bidirectional Counter
General Description
The ’AC/’ACT169 is fully synchronous 4-stage up/down
counter. The ’AC/’ACT169 is a modulo-16 binary counter. It
features a preset capability for programm ab le operation,
carry lookahead for easy cascading and a U/D input to con-
trol the direction of counting. All state changes, whether in
counting
n Synchronous counting and loading
n Built-In lookahead carry capability
n Presettable for programmable operation
n Outputs source/sink 24 mA
n ’ACT has TTL-compatible inputs
n Standard Microcircuit Drawing (SMD)
5962-91603
or
parallel
loading,
are
initiated
by
the
LOW-to-HIGH transition of the Clock.
Features
n I CC reduced by 50%
Logic Symbols
Pin
Nam es
Description
CEP
Count Enable Parallel Input
CET
Count Enable Trickle Input
CP
Clock Pulse Input
P 0 – P 3
Parallel Data Inputs
P E
Parallel Enable Input
U/D
Up-Down Count Control Input
Q 0 –Q 3
Flip-Flop Outputs
DS100276-1
TC
Terminal Count Output
IEEE/IEC
DS100276-2
FACT ™ is a trademark of Fairchild Semiconductor Corporation.
www.national.com
© 1998 National Semiconductor Corporation
DS100276
776556170.034.png 776556170.035.png 776556170.036.png 776556170.037.png 776556170.001.png 776556170.002.png 776556170.003.png 776556170.004.png 776556170.005.png 776556170.006.png 776556170.007.png
 
Connection Diagrams
Pin Assignment
for DIP and Flatpak
Pin Assignment
for LCC
DS100276-3
DS100276-4
Logic Diagram
DS100276-5
Please note that this diagram is provided only for the understanding of logic operations and should not be used to estimate propagation delays.
Functional Description
The ’AC/’ACT169 uses edge-triggered J-K-type flip-flops
and have no constraints on changing the control or data in-
put signals in either state of the Clock. The only requirement
is that the various inputs attain the desired state at least a
setup time before the rising edge of the clock and remain
valid for the recommended hold time thereafter. The parallel
load operation takes precedence over the ot her operations,
as indicated in the Mode Select Table. When PE is LOW, the
data on the P 0 –P 3 inputs enters the flip-flops on the next ris-
ing edge of the Clock. In order for counting to occur, both
CEP and CET must be LOW and PE must be HIGH; the U/D
input th en d etermines the direction of counting. The Terminal
Count (TC ) ou tput is normally HIGH and goes LOW, pro-
vided that CET is LOW, when a counter reaches zero in the
Co unt Down mode or reaches 15 in the Count Up mode. The
TC ou tput state is not a function of the Count Enable Parallel
(CEP) input level. If an illegal state occurs, the ’AC169 will
return to the legitimate sequence within two counts. Since
www.national.com
2
776556170.008.png 776556170.009.png 776556170.010.png 776556170.011.png
 
Functional Description (Continued)
the TC signal is derived by decoding the flip- flop states,
there exists the po ssib ility of decoding spikes on TC. For this
reason the use of TC as a clock signal is not recommended
(see logic equations below).
1.
State Diagrams
Count Enable = CEP •CET • PE
Up: TC = Q 0 • Q 1 • Q 2 Q 3 • (Up) • CET
2.
Down: TC = Q 0 • Q 1 •Q 2 •Q 3 •(Down)•CET
3.
Mode Select Table
PE
DS100276-6
CEP
CET
U/D
Action on Rising
Clock Edge
L
X
X
X
Load (P n to Q n )
H
L
L
H
Count Up (Increment)
H
L
L
L
Count Down (Decrement)
H
H
X
X
No Change (Hold)
H
X
H
X
No Change (Hold)
H = HIGH Voltage Level
L = LOW Voltage Level
X = Immaterial
3
www.national.com
776556170.012.png 776556170.013.png 776556170.014.png 776556170.015.png 776556170.016.png 776556170.017.png 776556170.018.png 776556170.019.png 776556170.020.png 776556170.021.png 776556170.022.png 776556170.023.png 776556170.024.png 776556170.025.png
 
Absolute Maximum Ratings (Note 1)
If Military/Aerospace specified devices are required,
please contact the National Semiconductor Sales Office/
Distributors for availability and specifications.
Supply Voltage (V CC )
Recommended Operating
Conditions
Supply Voltage (V CC )
’AC
2.0V to 6.0V
−0.5V to +7.0V
’ACT
4.5V to 5.5V
DC Input Diode Current (I IK )
V I = −0.5V
Input Voltage (V I )
0VtoV CC
−20 mA
Output Voltage (V O )
0VtoV CC
V I = V CC + 0.5V
+20 mA
Operating Temperature (T A )
54AC/ACT
DC Input Voltage (V I )
−0.5V to V CC + 0.5V
−55˚C to +125˚C
DC Output Diode Current (I OK )
V O = −0.5V
Minimum Input Edge Rate (
D
V/
D
t)
−20 mA
’AC Devices
V IN from 30% to 70% of V CC
V CC @ 3.3V, 4.5V, 5.5V
V O = V CC + 0.5V
+20 mA
DC Output Voltage (V O )
−0.5V to V CC + 0.5V
125 mV/ns
DC Output Source
or Sink Current (I O )
Minimum Input Edge Rate (
D
V/
D
t)
± 50 mA
’ACT Devices
V IN from 0.8V to 2.0V
V CC @ 4.5V, 5.5V 125 mV/ns
Note 1: Absolute maximum ratings are those values beyond which damage
to the device may occur. The databook specifications should be met, without
exception, to ensure that the system design is reliable over its power supply,
temperature, and output/input loading variables. National does not recom-
mend operation of FACT ™ circuits outside databook specifications.
DC Characteristics for ’AC Family Devices
DC V CC or Ground Current
per Output Pin (I CC or I GND )
± 50 mA
Storage Temperature (T STG )
−65˚C to +150˚C
Junction Temperature (T J )
CDIP
175˚C
54AC
T A =
Symbol
Parameter
V CC
Units
Conditions
(V)
−55˚C to +125˚C
Guaranteed
Limits
V OUT = 0.1V
V IH
Minimum High Level
3.0
2.1
Input Voltage
4.5
3.15
V
or V CC − 0.1V
5.5
3.85
V OUT = 0.1V
V IL
Maximum Low Level
3.0
0.9
Input Voltage
4.5
1.35
V
or V CC − 0.1V
5.5
1.65
I OUT = −50 µA
V OH
Minimum High Level
3.0
2.9
Output Voltage
4.5
4.4
V
5.5
5.4
(Note 2)
V IN = V IL or V IH
3.0
2.4
I OH = −12 mA
4.5
3.7
V
I OH = −24 mA
5.5
4.7
I OH = −24 mA
I OUT = 50 µA
V OL
Maximum Low Level
3.0
0.1
Output Voltage
4.5
0.1
V
5.5
0.1
(Note 2)
V IN = V IL or V IH
3.0
0.50
I OL =12mA
4.5
0.50
V
I OL =24mA
5.5
0.50
I OL =24mA
± 1.0
V I = V CC , GND
I IN
Maximum Input
5.5
µA
Leakage Current
www.national.com
4
776556170.026.png 776556170.027.png 776556170.028.png 776556170.029.png
 
DC Characteristics for ’AC Family Devices (Continued)
54AC
T A =
Symbol
Parameter
V CC
Units
Conditions
(V)
−55˚C to +125˚C
Guaranteed
Limits
V OLD = 1.65V Max
I OLD
Minimum Dynamic
Output Current (Note 3)
5.5
50
mA
V OHD = 3.85V Min
I OHD
5.5
−50
mA
V IN = V CC
I CC
Maximum Quiescent
5.5
80.0
µA
Supply Current
or GND
Note 2: All outputs loaded; thresholds on input associated with output under test.
Note 3: Maximum test duration 2.0 ms, one output loaded at a time.
Note 4: I IN and I CC @ 3.0V are guaranteed to be less than or equal to the respective limit @ 5.5V V CC .
I CC for 54AC @ 25˚C is identical to 74AC @ 25˚C.
DC Characteristics for ’ACT Family Devices
54ACT
Symbol
Parameter
V CC
T A =
Units
Conditions
(V)
−55˚C to +125˚C
Guaranteed
Limits
V IH
Minimum High Level
4.5
2.0
V
V OUT = 0.1V
Input Voltage
5.5
2.0
or V CC − 0.1V
V IL
Maximum Low Level
4.5
0.8
V
V OUT = 0.1V
Input Voltage
5.5
0.8
or V CC − 0.1V
V OH
Minimum High Level
4.5
4.4
V
I OUT = −50 µA
Output Voltage
5.5
5.4
(Note 5)
V IN = V IL or V IH
4.5
3.70
V
I OH = −24 mA
5.5
4.70
I OH = −24 mA
V OL
Maximum Low Level
4.5
0.1
V
I OUT = 50 µA
Output Voltage
5.5
0.1
(Note 5)
V IN = V IL or V IH
4.5
0.50
V
I OL =24mA
5.5
0.50
I OL =24mA
± 1.0
V I = V CC , GND
I IN
Maximum Input
5.5
µA
Leakage Current
V I = V CC − 2.1V
I CCT
Maximum
5.5
1.6
mA
I CC /Input
V OLD = 1.65V Max
I OLD
Minimum Dynamic
Output Current (Note 6)
5.5
50
mA
I OHD
5.5
−50
mA
V OHD = 3.85V Min
I CC
Maximum Quiescent
5.5
80.0
µA
V IN = V CC
Supply Current
or GND
Note 5: All outputs loaded; thresholds on input associated with output under test.
Note 6: Maximum test duration 2.0 ms, one output loaded at a time.
Note 7: I CC for 54ACT @ 25˚C is identical to 74ACT @ 25˚C.
5
www.national.com
776556170.030.png 776556170.031.png 776556170.032.png 776556170.033.png
 