S73if_e.pdf

(1122 KB) Pobierz
Preface, Contents
1
Product Overview
What you Should Know about the
Integrated Functions
2
SIMATIC
Frequency Meter Integrated
Function
3
4
S7-300 Programmable Controller
Integrated Functions
CPU 312 IFM/314 IFM
Counter Integrated Function
Counter A/B Integrated Function
(CPU 314 IFM)
5
Positioning Integrated Function
(CPU 314 IFM)
6
Manual
Appendices
Technical Specifications of the
Frequency Meter Integrated
Function
A
Technical Specifications of the
Counter Integrated Function
B
Technical Specifications of the
Counter A/B Integrated Function
C
Technical Specifications of the
Positioning Integrated Function
D
E
Troubleshooting
F
SIMATIC S7 Reference Literature
Using the Integrated Functions
with the OP 3
G
Glossar, Index
EWA 4NEB 710 6058-02a
Edition 2
812534117.048.png 812534117.052.png 812534117.053.png 812534117.054.png 812534117.001.png 812534117.002.png 812534117.003.png 812534117.004.png 812534117.005.png 812534117.006.png 812534117.007.png 812534117.008.png 812534117.009.png 812534117.010.png 812534117.011.png 812534117.012.png 812534117.013.png 812534117.014.png 812534117.015.png 812534117.016.png
Safety Guidelines
This manual contains notices which you should observe to ensure your own personal safety, as
well as to protect the product and connected equipment. These notices are highlighted in the
manual by a warning triangle and are marked as follows according to the level of danger:
Danger
indicates that death, severe personal injury or substantial property damage will result if proper
precautions are not taken.
!
Warning
indicates that death, severe personal injury or substantial property damage can result if proper
precautions are not taken.
!
Caution
indicates that minor personal injury or property damage can result if proper precautions are not taken.
!
Note
draws your attention to particularly important information on the product, handling the product, or
to a particular part of the documentation.
Qualified Personnel
The device/system may only be set up and operated in conjunction with this manual.
Only qualified personnel should be allowed to install and work on this equipment. Qualified
persons are defined as persons who are authorized to commission, to ground, and to tag circuits,
equipment, and systems in accordance with established safety practices and standards.
Correct Usage
Note the following:
Warning
This device and its components may only be used for the applications described in the catalog or the
technical description, and only in connection with devices or components from other manufacturers
which have been approved or recommended by Siemens.
This product can only function correctly and safely if it is transported, stored, set up, and installed
correctly, and operated and maintained as recommended.
!
Trademarks
SIMATIC
and SINEC
are registered trademarks of SIEMENS AG.
Third parties using for their own purposes any other names in this document which refer to trade-
marks might infringe upon the rights of the trademark owners.
Copyright
Siemens AG 1996 All rights reserved
The reproduction, transmission or use of this document or its
contents is not permitted without express written authority.
Offenders will be liable for damages. All rights, including rights
created by patent grant or registration of a utility model or design, are
reserved.
Siemens AG
Automation Group
Industrial Automation Systems
P.O. Box 4848, D-90327 Nuremberg
Disclaimer of Liability
We have checked the contents of this manual for agreement with the
hardware and software described. Since deviations cannot be pre-
cluded entirely, we cannot guarantee full agreement. However, the
data in this manual are reviewed regularly and any necessary cor-
rections included in subsequent editions. Suggestions for improve-
ment are welcomed.
Technical data subject to change.
Siemens AG 1996
Siemens Aktiengesellschaft
Order No. 6ES7 398-8CA00-8BA0
Integrated Functions CPU 312 IFM/CPU 314 IFM
EWA 4NEB 710 6058 02
ii
812534117.017.png 812534117.018.png
 
812534117.019.png 812534117.020.png 812534117.021.png 812534117.022.png 812534117.023.png 812534117.024.png 812534117.025.png 812534117.026.png 812534117.027.png 812534117.028.png 812534117.029.png 812534117.030.png 812534117.031.png 812534117.032.png 812534117.033.png
 
Preface
Purpose
The information in this manual enables you to solve automation tasks with
the integrated functions of the CPU 312 IFM or CPU 314 IFM.
Audience
This manual is addressed to users who wish to use the integrated functions of
the CPU 312 IFM/CPU 314 IFM
Users will find the following information:
Basic information on the integrated functions
A description of the Frequency Meter, Counter, Counter A/B and Posi-
tioning integrated functions
The technical specifications of the integrated functions
The use of the integrated functions with the OP3.
The hardware of the CPUs and the S7-300 modules is described in the manu-
als S7-300 Programmable Controller, Installation and Hardware and S7-300,
M7-300 Programmable Controllers, Module Specifications.
Scope of this
Manual
This manual is valid for:
CPU
Order No.
From Product Versions
CPU 312 IFM
6ES7 312-5AC01-0AB0
01
CPU 314 IFM
6ES7 314-5AE02-0AB0
01
This manual describes the integrated functions contained in the CPU 312
IFM and CPU 314 IFM at the date of issue of the manual. We reserve the
right to describe modifications to the integrated functions in a separate Prod-
uct Information.
Changes From the
Previous Version
Compared to the previous version, the manual Integrated Functions with the
order number 6ES7 398-8CA00-8BA0, this manual has been extended with a
description of the new features of the Frequency Meter integrated function.
Integrated Functions CPU 312 IFM/CPU 314 IFM
EWA 4NEB 710 6058-02a
iii
812534117.034.png 812534117.035.png 812534117.036.png 812534117.037.png 812534117.038.png 812534117.039.png 812534117.040.png
 
Preface
Approbations
The following approbations exist for the S7-300:
UL-Recognition-Mark
Underwriters Laboratories (UL) in accordance with
Standard UL 508, File No. 116536
CSA-Certification-Mark
Canadian Standard Association (CSA) in accordance with
Standard C22.2 No. 142, File No. LR 48323
CE Mark
Our products conform to the requirements of EC Directive 89/336/EEC
“Electromagnetic Compatibility” and the harmonized European standards
(ENs) listed therein.
The EU certificates of conformity are held at the disposal of the competent
authorities in accordance with the above-named EC directive, Article 10, at
the following address:
Siemens Aktiengesellschaft
Bereich Automatisierungstechnik
A & D AS E 14
Postfach 1963
D-92209 Amberg
Federal Republic of Germany
Recycling and
Disposal
The SIMATIC S7-300 is an environmentally-friendly product!
The SIMATIC S7-300 is characterized by the following points:
The housing plastic is equipped with halogen-free flameproofing despite
its high level of fireproofing.
Laser labeling (that is, no paper labels)
Plastics materials labeled in accordance with DIN 54840
Reduction in materials used thanks to more compact design, fewer com-
ponents thanks to integration in ASICs
The SIMATIC S7-300 can be recycled thanks to the low level of pollutants in
its equipment.
Please contact the following address for environmentally-friendly recycling
and disposal of your old SIMATIC equipment:
Siemens Aktiengesellschaft
Technische Dienstleistungen
ATD TD 3 Kreislaufwirtschaft
Postfach 32 40
D-91050 Erlangen
Telephone: ++49 9131/7-3 36 98
Fax: ++49 9131/7-2 66 43
This Siemens service department provides a comprehensive and flexible dis-
posal system with customized advice at a fixed price. After disposal, you
receive a breakdown of the dismantling procedure with information on the
proportions of materials and the relevant material record documentation.
Integrated Functions CPU 312 IFM/CPU 314 IFM
EWA 4NEB 710 6058-02a
iv
812534117.041.png
Preface
Scope of the Docu-
mentation Package
The documentation should be ordered separately from the CPU:
CPU
Documentation
CPU 312 IFM
S7-300 Programmable Controller, Installation and
Hardware Manual
or
S7-300 and M7-300 Programmable Controllers,
Module Specifications Reference Manual
CPU 314 IFM
S7-300 Programmable Controller Instruction List
Integrated Functions CPU 312 IFM/314 IFM Manual
In Appendix F , you will find a list of documentation which you require for
programming and starting up of the S7-300.
CD-ROM
You can also order the entire SIMATIC S7 documentation as SIMATIC S7
reference documentation on CD-ROM.
How to Use
This Manual
This manual features the following access aids for fast reference to specific
information:
The manual starts with a complete table of contents, also including a list
of all figures and tables appearing in the manual.
In the various chapters, the headlines on the left margin highlight the con-
tents of the particular section.
The glossary in the last chapter of the Appendix explains important terms
employed in the manual.
The index at the end of this manual enables you to get fast access to the
information required.
Additional
Assistance
If you have any queries about the products described in this manual, please
contact your local Siemens representative. You can find the addresses of Sie-
mens representatives in the Appendix “Siemens Worldwide” of the manual
S7-300 Programmable Controller, Installation and Hardware .
If you have any questions or suggestions concerning this manual, please fill
in the form at the end of this manual and return it to the specified address.
Please feel free to enter your personal assessment of the manual in the form
provided.
We offer a range of courses to help get you started with the SIMATIC S7 pro-
grammable controller. Please contact your local training center or the central
training center in Nuremberg, D-90327 Germany, Tel. +49 911 895 3154.
Integrated Functions CPU 312 IFM/CPU 314 IFM
EWA 4NEB 710 6058-02a
v
812534117.042.png 812534117.043.png 812534117.044.png 812534117.045.png 812534117.046.png 812534117.047.png 812534117.049.png 812534117.050.png 812534117.051.png
 
Zgłoś jeśli naruszono regulamin