04_11_08_hp_integrity_rx2620_2_server_ordering_and_configuration_guides.pdf
(
414 KB
)
Pobierz
HP Integrity rx2620-2 Server Ordering and
Configuration guides
Launch date 11/8/04
Note: This is an interim document. The information will be incorporated into the 12/1/04 online update of the
HP 9000 Ordering and Configuration Guides.
HP Integrity rx2620-2 Server Ordering and Configuration Guides
HP Integrity rx2620-2 Server
Note
: This information can also be found in QuickSpecs at:
http://h18000.www1.hp.com/products/quickspecs/11716_div/11716_div.HTML
Table 1 HP Integrity rx2620-2 Specifications
Server Model Number
rx2620-2
Maximum Network Interface Cards
–
see supported I/O table
Server Product Numbers
2
1000Base-SX
4
Model rx2620 Base System with no CPUs. System
AB459A
1000Base-TX
4
includes core I/O and one power supply. Memory,
10/100Base-TX
4
CPUs and Storage must be purchased separately.
Dual-port X.25
4
Model rx2620 base system with one 1.6-GHz/3-MB
AB332A
4-port 10/100Base-TX
4
CPU (200-MHz system bus, 400 MT/s). System
includes
PCI-X dual-port GigE-TX
4
one CPU, core I/O, and one power supply.
PCI-X dual-port GigE-SX
4
Model rx2620 base system with one 1.3-GHz/3-MB
AB333A
Electrical Characteristics
CPU (200-MHz system bus, 400 MT/s). System
includes
one CPU, core I/O, and one power supply
AC Input power
100-240V 50/60 Hz
1 included, 2
nd
for N+1
Hot swap Power supplies
Redundant AC power inputs
1 included, 2
nd
for N+1
Current requirements at 230V
4 A (shared across inputs)
Typical maximum power dissipation
600 Watts
Supported Processors
Theoretical maximum power dissipation
1,350 Watts
1.3-GHz Intel® Itanium 2® processor
kW rating for UPS loading
1.3
Cache
3 MB
Typical Heat dissipation (BTUs/hour)
1,945
Floating-point Coprocessor included
Yes
Maximum Heat dissipation (BTUs/hour)
4,375
1.6-GHz Intel® Itanium 2® processor
Cache
3 MB
Site Preparation
Floating Point Coprocessor included
Yes
Site planning and installation included
No
Rack depth (mm/inches)
680 mm/26.8 in
System Memory
Rack width (mm/inches)
482 mm/19 in
Minimum memory
1 GB
Rack height (EIA/mm/inches)
2U/ 86 mm/3.4 in
Maximum memory capacity
24 GB
Pedestal depth (mm/inches)
672 mm/26.5 in
Pedestal width (mm/inches)
297 mm/ 11.7 in
Internal Disks
Pedestal height (mm/inches)
494 mm/ 19.5 in
Maximum disk mechanisms
3
Weight (kg/lbs) Max.
25 kg/56 lbs
Maximum disk capacity
438 GB
Environmental Characteristics
Standard Integrated I/O
Acoustics (operator/bystander) at 25
C
<6.8 Bels LwA
Ultra320 SCSI
–
LVD
2 channels
Operating Temperature (up to 5000 ft)
1
+5
to +35
C
10/100/1000Base-T (RJ-45 connector)
2 port
Non-operating Temperature
–40
to +70
degrees C
RS-232 serial ports
5
Maximum rate of temperature change
10
C/hour
10/100Base-T management port (RJ-45 connector)
Yes
Operating relative humidity
15% to 80% RH non-cond.
VGA graphics
Optional
Non-operating relative humidity
8% to 85% non-condensing
USB
4
Operating altitude above sea level
3000 m (10000 ft) max
Non-operating altitude above sea level
4600 m (15000 ft) max
I/O Buses and Slots
Total PCI-X/PCI Slots
4
Regulatory Compliance
All four slots are 133-MHz, 64-bit slots on dedicated PCI-X buses
RMN
RSVLA-0403
Electromagnetic
Complies with FCC Rules and Regulations, Part 15
Maximum Mass Storage Host Bus Adapters
–
see supported I/O table
interference
as a Class A digital device. Manufacturer’s
Ultra160 SCSI
–
LVD
3
Declaration to EN55022 Level A, VCCI Registered,
Dual-port Ultra160 SCSI
–
LVD
3
Class A, Korea RLL, CCC, BMSI Taiwan
Smart Array Ultra160 SCSI RAID
3 (only 1 for
Safety
CSA NRTL Certified, EN 60950-1
internal
drives)
HP Integrity rx2620-2 Server Ordering and Configuration Guides
1
Internal and Channel Partner Use Only – Launch date 11/08/04
HP Integrity rx2620-2 Server Ordering and Configuration Guides
2-Gb single-port fibre channel
4
1
Maximum operating temperature range up to 5000 feet. For higher altitudes, de-rate the maximum temperature by 2°C/1000 feet above 5000 feet.
2
Two power cords are shipped with each system; one connects the system to the rack PDU and one enables connection to a wall socket. Localized cords are included
at the Distribution center.
Overview
Figure 1 HP Integrity rx2620-2 System Overview (Front View)
Optional Management
Processor Card
Intel ® Itanium 2 ® CPUs
Hot Swap Fans
DVD-ROM
4 PCI-X I/O Slots
12 DDR Memory DIMMS
Hot Swap Power
Supplies
Hot Plug Disk Drives
2
HP Integrity rx2620-2 Server Ordering and Configuration Guides
Internal and Channel Partner Use Only – Launch date 11/08/04
HP Integrity rx2620-2 Server Ordering and Configuration Guides
Figure 2 HP Integrity rx2620-2 System Architecture
Intel ®
Itanium 2 ®
Intel ®
Itanium 2 ®
6.4 GB/s
zx1
mio
4.25 GB/s
4.25 GB/s
4.0 GB/s
zx1
ioa
zx1
ioa
zx1
ioa
zx1
ioa
zx1
ioa
zx1
ioa
zx1
ioa
Optional Core management: 10/100Base-T, VGA, RS-232
PCI-X 133 (1 GB/s)
Core I/O: 2xU320 SCSI, 2x10/100/1000Base-T
PCI-X 133 (0.5 GB/s)
IDE (removable media), USB
PCI-X 133 (0.5 GB/s)
PCI-X 133 (0.5 GB/s)
Features
Table 2 HP Integrity rx2620-2 Features
Minimum System
• One 64-bit Intel® Itanium 2® CPU: Either 1.3-GHz/3.0-MB cache (200-MHz system bus, 400MT/s) or
1.6-GHz/3-MB cache (200-MHz system bus, 400 MT/s)
• 1-GB PC2100 ECC Registered DDR266A SDRAM (4×256MB DIMMs)
• One power supply
Maximum Server Capacities
• Two 64-bit Intel® Itanium 2® CPUs: Either 1.3-GHz/3.0-MB cache (200-MHz system bus, 400 MT/s) or
1.6-GHz/3-MB cache (200-MHz system bus, 400 MT/s)
• 24-GB PC2100 ECC Registered DDR266A SDRAM (12×2GB DIMMs)
• Two Hot swap power supplies, providing N+1 protection for power supplies and power input
• Four PCI-X/PCI IO adapter cards
• One internal DVD ROM or CD-RW/DVD-ROM combo drive
• Three internal hot-plug LVD SCSI disks
Standard System Features
• Three Operating System support: HP-UX 11i version 2, Windows Server 2003 Enterprise Edition, and Linux
Note: OpenVMS will be available in Q1 calendar year 2005.
• Dual-channel Ultra320 SCSI controller, 2 internal disks on one channel, 1 internal disk on a second channel
• External Ultra320 SCSI port
• Two ports 10/100/1000Base-TX LAN (auto speed sensing, RJ-45 connector)
• Optional Management Processor for remote management and HA monitoring
• Telnet and web console via 10/100Base-TX management LAN (RJ-45 connector)
• Two general purpose RS-232 serial ports
• Three RS-232 serial ports linked to the management processor (multiplexed from a single DB-25 port)
• Factory integration of CPUs, memory, disk drives, removable media, and I/O cards
• Rackmountable into 19-inch cabinets
• Optional stand-alone pedestal mount
HP Integrity rx2620-2 Server Ordering and Configuration Guides
3
Internal and Channel Partner Use Only – Launch date 11/08/04
HP Integrity rx2620-2 Server Ordering and Configuration Guides
• One-year warranty with next business day on-site
High Availability
• N+1 Hot swap cooling
• One Hot swap power supply standard–optional second hot swap power supply for N+1 protection
• On-line memory page deallocation
• ECC protected DDR memory
• Memory chip spare to overcome single DRAM chip failures
• Dynamic Processor resilience and deallocation
• UPS power management
• Hot Plug internal disks
• Two independent Ultra SCSI channels to internal disks for mirroring across disks and channels
• Journal file system for HP-UX
• Auto reboot
• HP MC/ServiceGuard for HP-UX
• Microsoft Windows Cluster Service
• HP ServiceGuard Extension for RAC for HP-UX
• ServiceGuard Manager for HP-UX
• Insight Manager 7—proactive fault management
• EMS HA Monitors for HP-UX
• ECM Toolkit for HP-UX
• HP Surestore AutoPath for HP-UX
• MirrorDisk for HP-UX
Security
• Separate LAN for system management
• Password protection on console port
• Disablement of remote console ports
• SSL encryption on web console
Manageability
• HP Ignite-UX for installation and deployment of the operating system
• HP Software Distributor-UX for software and patch management
• HP Servicecontrol Suite for HP-UX
• HP System Insight Manager (SIM) for Windows and Linux
• Management processor for comprehensive remote management of HP-UX, Windows, and Linux
• Optional Integrated Lights-Out (iLO) Advanced Pack activation key and license
• Process Resource Manager for HP-UX workload management
Configuration
CPU Configuration
The HP Integrity rx2620-2 is a symmetrical multiprocessing (SMP) server supporting up to two
high-performance 64-bit Itanium 2 processors. Processor speeds cannot be mixed within the same system.
Processor Details
• 1.3-GHz with 3.0-MB Level 3 Cache
• 1.6-GHz with 3.0-MB Level 3 Cache
All processors support:
• Level 2 Cache: 256 KB
• Level 1 Cache: 32 KB
• 200-MHz System Bus (400 MT/s)
• Single-bit cache error correction
• 50-bit physical addressing
• 64-bit virtual addressing
• 4 GB maximum page size
4
HP Integrity rx2620-2 Server Ordering and Configuration Guides
Internal and Channel Partner Use Only – Launch date 11/08/04
Plik z chomika:
JolanPOL
Inne pliki z tego folderu:
04_11_rx4640_8_customer_presentation_final.ppt
(5403 KB)
04_11_incredibles_rx2620_cust_presentation.ppt
(4036 KB)
04_11_08_hp_integrity_rx4640_8_server_ordering_and_configuration_guides.pdf
(654 KB)
04_11_08_hp_integrity_rx2620_2_server_ordering_and_configuration_guides.pdf
(414 KB)
rx6600.pdf
(1107 KB)
Inne foldery tego chomika:
AMD
Backup
Backup diagrams
Biblioteki MSL
BladePower_Sizer
Zgłoś jeśli
naruszono regulamin