Fault
Component Description
Explanation of Malfunction
1
Temperature Selector Wheel - Right
Check the connection of the black component plug PIN 6 to the right temperature selector wheel. Also
check that there is at least approx. 5 volt voltage on the selector wheel. If you can't find any fault, the
component should be replaced.
4
Heater Sensor - Right
Check the connection of the white component plug PIN 2 to the Right Heater Sensor. Measure the
voltage at the unplugged heater sensor. Minimum 5 volts. If ok, replace the sensor.
7
Vaporizer Sensor
Check the connection of the white component plug PIN 5 to the Vaporizer Sensor. Measure the
voltage at the unplugged Vaporizer Sensor. Minimum 5 volts. If ok, replace the sensor.
10
Outside Sensor
Check the connection of the white component plug PIN 4 to to the Outside Sensor. Measure the
voltage at the unplugged sensor. Minimum 5 volts. If ok, replace the sensor.
13
Inside Sensor
Check the connection of the black component plug PIN 3 to the Inside Sensor. Measure the voltage at
the unplugged sensor. Minimum 5 volts. If ok, replace the sensor.
16
Inside Sensor Blower
Check the connection of the blue component plug PIN 18 to the inside sensor blower. If the
connection is ok, the component should be replaced.
25
Temperature Selector Wheel - Left
Check the connection of the black component plug PIN 5 to the temperature selector wheel. Measure
the voltage at the selector wheels. Approx. 5 volts. If ok, replace the sensor.
28
Heater Sensor - Left
Check the connection of the white component plug PIN 3 to the heater sensor. Measure the voltage at
the unplugged sensor. Minimum 5 volts. If ok, replace the sensor.
31
Air quantity selector wheel
Check the connection of the black component plug PIN 4 to the air quantity selector wheel. Measure
the voltage at the selector wheels. Approx. 5 volts. If ok, replace the sensor.
34
Layering Selector Wheel
Check the connection of the white component plug PIN 6 to the layering selector wheel. Measure the
voltage at the selector wheels. Approx. 5 volts. If ok, replace the sensor.
38
Additional Water Pump Relay
Check the connection of the blue component plug PIN 19 to the additional water pump relay. If the
connection is operative, the relay should be replaced.
817233821.028.png 817233821.029.png 817233821.030.png 817233821.031.png 817233821.001.png 817233821.002.png 817233821.003.png 817233821.004.png 817233821.005.png 817233821.006.png 817233821.007.png 817233821.008.png 817233821.009.png 817233821.010.png 817233821.011.png 817233821.012.png
 
40
Water Valve - Left
Check the connection of the black component plug PIN 22 to the water valve. If the connection is
operative, the water valve should be replaced.
44
Climate Relay/Additional Blower Relay
Check the connection of the blue component plug PIN 22 to the climate relay. If the connection is
operative, the climate relay/additional blower relay should be replaced.
46
Water Valve - Right
Check the connection of the black component plug PIN 15 to the water valve. If the connection is
operative, the water valve should be replaced.
47
Decoupling Relay Air Conditioning
Check the connection of the black component plug PIN 9 to the Motronic relay. If the connection is
operative, the relay should be replaced. NOTE: Also check the blower relay.
48
Rear Window Heater Relay
Check the connection of the blue component plug PIN 20 to the rear window heater relay. If the
connection is operative, the relay should be replaced.
52
Fresh Air Flap Motor
Check the connection of the blue component plug PIN 10, 11, 12 and 13 to the fresh air flap motor.
Check the voltage at the motor (appox. 12 volt). If the voltage and the cable connection are operative,
the Fresh Air Flap Motor should be replaced.
55
Air Flow Flap Motor
Check the connection of the blue component plug PIN 6, 7, 8 and 9 to the air flow flap motor. Check
the voltage at the motor (appox. 12 volt). If the voltage and the cable connection are operative, the Air
Flow Flap Motor should be replaced.
56
Automatic Air Flow Control
Check the connection of the black component plug PIN 8 to the AUC-conponent. It is also possible
that the automatic air flow control component is defective!
61
Layering Flap Motor
Check the connection of the black component plug PIN 23, 24, 25 and 26 to the right layering flap
motor. Check the voltage at the motor (appox. 12 volt). If the voltage and the cable connection are
operative, the Layering Flap Motor should be replaced.
92
Connection fault on connecter 50
Check the connection of the black component plug PIN 26 for a break or short.
94
Standing heater / Standing ventilation
Check the connection of the white component plug PIN 7 and 10 for a break or short.