ghb4435b_e.pdf
(
96 KB
)
Pobierz
S7-CPs Manual / Part B3
Description of the CP 443-5 Basic
6GK7 443–5FX01–0XE0
Version 3 and higher
(Firmware version V3.2 and higher )
for SIMATIC S7–400 / S7–400H
Status and fault LEDs
Mode selector
PROFIBUS interface
(9-pin sub-D female
connector)
Notes on the Product
Notes on the Product
Note
All the notices in the
Manual
shipped with this device are valid and must be
adhered to.
Compatibility with the Previous Version
Note
Make sure that you read the information regarding
extended functionality and
restrictions
in Chapter 2 of this manual!
S7-CPs for PROFIBUS Manual / Part B3 – CP 443-5 Basic
C79000-G8976-C161-02
2
Contents
Contents – Part A
PROFIBUS–CPs – General Information
. . . . . . . . . . . . . . . . . . . . . . .
see general part
Note
Please remember that Part A of the manual also belongs to the description of the
CPs. Among other things, this includes an explanation of the safety, related
notices and other information that applies to all S7 CPs for Industrial Ethernet.
You can also obtain this general section from the Internet:
http://www4.ad.siemens.de/view/cs/de/877403
7
Contents – Part B3
Notes on the Product
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3–2
1
Properties / Services
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3–4
2
Compatibility with the Previous Product
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3–7
3
Requirements for Use
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3–8
4
Installation and Commissioning
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3–11
5
Displays and Mode Selector
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3–12
6
Performance Data
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3–14
6.1
Supported Transmission Rates
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3–14
6.2
Characteristics of S5-Compatible Communication
(SEND/RECEIVE Interface) on FDL Connections
. . . . . . . . . . . . . . . . . . . .
B3–15
6.3
Data of FMS Connections
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3–16
6.4
Characteristics of S7 Communication
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3–18
6.5
Maximum Number of Connections in Total
. . . . . . . . . . . . . . . . . . . . . . . . . .
B3–19
6.6
Time-of-day Synchronization
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3–19
6.7
Use in Fault-Tolerant Systems
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3–20
6.8
Other Characteristics
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3–21
7
Replacing Older Modules
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3–22
8
Technical Data
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
B3–23
S7-CPs for PROFIBUS Manual / Part B3 – CP 443-5 Basic
C79000-G8976-C161-02
B3–3
Features / Services
1
Features / Services
Application
The CP 443-5 Basic communications processor is designed for use in a SIMATIC
S7-400 (standard) and S7-400H (fault-tolerant system) programmable controller. It
allows the S7-400 / S7-400H to be connected to a PROFIBUS field bus system.
Services
The current version of the CP 443-5 Basic supports the following communication
services in the standard and H systems:
FMS Connections
PROFIBUS–FMS (complying with EN 50170, FMS client and server
functionality)
as FMS master for the following types of connection:
–
MMAC: Master–master acyclic
–
MSAC: Master–slave acyclic
–
MSAC_SI: Master–slave acyclic with slave initiative
–
MSCY: Master slave cyclic
–
BRCT (broadcast): Sending to all FMS stations
S7 communication and PG/OP communication
–
PG functions with upload / download of FM modules, configuration /
diagnostics and routing
Note on routing: Dynamic switchover to alternative paths (for example if
there is a problem on one of the possible transmission paths) is not
supported.
–
Operator control and monitoring functions (HMI)
–
Data exchange using communication function blocks on S7 connections
(fault-tolerant S7 connections also possible)
1
)
1)
Blocks for S7 communication (see also STEP 7 online help or
“System Software for S7-300/400 System and Standard Functions” manual)
:
BSEND
SFB 12
BRCV
SFB 13
PUT
SFB 14
GET
SFB 15
USEND
SFB 8
URCV
SFB 9
STATUS
SFB 22
START
SFB 19
STOP
SFB 20
RESUME
SFB 21
USTATUS
SFB 23
CONTROL
SFC 62
S7-CPs for PROFIBUS Manual / Part B3 – CP 443-5 Basic
C79000-G8976-C161-02
B3–4
Features / Services
S5–compatible communication (SEND/RECEIVE interface) over FDL
connections of the following type:
–
specified FDL connections
–
free layer 2 connections
–
broadcast
–
multicast
Time–of–day Synchronization over PROFIBUS
–
The CP forwards time-of-day synchronization frames from the LAN to the
station (CPU = time slave) or from the station to the LAN (CPU= time
master) or this station is synchronized via a different LAN and the
time-of-day synchronization frame must be forwarded over PROFIBUS for
the synchronization of further stations.
–
Time-of-day status value, standard/daylight saving time switchover,
synchronization status
The services of the CP 443-5 Basic module listed above can be used at the same
time.
PG Functions with
upload / download of FM modules
configuration / diagnostics
routing
Configuration
When configuring, you must use STEP 7 version V5.1 SP2 or higher; for FDL
connections and diagnostic functions you must already have installed the NCM S7
for PROFIBUS optional package, delivered with STEP 7. Depending on the version
you are using, note the following characteristics and special features:
STEP 7 version 5.0 and higher Service Pack 2
This version is the minimum requirement for the routing of PG functions and
time-of-day synchronization.
STEP 7 version 5.0 Service Pack 3 Hotfix 3
The optional package “SIMATIC S7 H Systems” must also be installed to
configure fault-tolerant systems.
The following functions of the CP are not yet supported in this configuration
environment when using fault-tolerant systems:
–
Single (non-redundant) communications connections cannot be configured in
a fault-tolerant system;
STEP 7 version 5.1
When configuring fault-tolerant systems you must also install the “SIMATIC S7
H Systems” optional package.
S7-CPs for PROFIBUS Manual / Part B3 – CP 443-5 Basic
C79000-G8976-C161-02
B3–5
Plik z chomika:
masterkom
Inne pliki z tego folderu:
ET200iS_e.pdf
(22821 KB)
DOC_AS_PL_S7300_HW_moduly.pdf
(7881 KB)
DPPA_E.PDF
(4575 KB)
dyn_funktion_e.pdf
(4571 KB)
Cpu210_e.pdf
(1429 KB)
Inne foldery tego chomika:
Autoryzacja
Kable
Logo
OP Panels
S5
Zgłoś jeśli
naruszono regulamin